Victron Phoenix Smart IP43 Charger 12/50 (1+1) | PSC125051095

Only 5 left in stock
SKU PSC125051095
$471.75

Compatible accessories & add-ons

Still have questions?

We're here to help! Give us a call and talk with a US-based technical expert.

Give us a call1-888-501-1846
Victron Phoenix Smart IP43 Charger 12/50 (1+1) | PSC125051095
1/1
Hover to zoom

Smart dual-output shore-power charging

Victron Phoenix Smart IP43 Charger 12/50 (1+1) | PSC125051095

A premium 12V 50A Victron charger with a dedicated starter-battery output, Bluetooth, VE.Direct, and universal 120/240V shore-power capability.

The Victron Phoenix Smart IP43 charger solves a common marine and RV challenge: charging a large 12V house battery bank while keeping a separate starter battery ready. This PSC125051095 12/50(1+1) battery charger supplies up to 50A to the house bank plus a limited 4A starter-battery output, with programmable lithium profiles, Bluetooth VictronConnect control, and VE.Direct system integration.

50A
House-bank output
4A
Starter output
85–250VAC
Universal input
Bluetooth
VictronConnect
VE.Direct
GX integration
5 years
Victron warranty

Intelligent charging in one compact unit

1+1 charging House and starter banks
Lithium ready Programmable LiFePO4 profile
Fanless cooling Natural convection
Power-supply mode Configurable DC output
Remote on/off BMS and switch control
Programmable relay Alarm and event control

Dual Output: The “1+1” Advantage

Charge the house bank and maintain the starter battery from one AC source.

The primary output delivers up to 50A of multi-stage charging power to a substantial 12V house bank. The secondary “+1” output is limited to 4A maximum and operates at a slightly lower output voltage, making it ideal for maintaining or topping up a separate starter battery.

This design reduces charger count and wiring complexity in boats, motorhomes, commercial vehicles, and off-grid systems that use separate house and starting batteries.

Main 50A Output for House Batteries

The main output rapidly replenishes a 12V house bank after extended anchoring, boondocking, or off-grid use. Low-current mode reduces the output to 25A when a lower charge rate is preferred.

Secondary 4A Starter-Battery Output

The limited starter output keeps an engine-starting or generator battery topped up while the primary channel handles the house bank. It is a maintenance output, not a second full-current 50A charger.

Intelligent, Programmable Lithium Charging

Configure the charger for Epoch LiFePO4, AGM, GEL, flooded lead-acid, or other approved 12V batteries.

Victron’s adaptive charging system provides selectable normal, high, and lithium modes. Lead-acid profiles use an adaptive six-stage algorithm, while the built-in lithium profile uses a dedicated three-stage process. The charge algorithm is also fully programmable through Bluetooth or VE.Direct, allowing the installation to match the exact voltage and current limits published by the battery manufacturer.

The lithium preset uses 14.2V absorption, no conventional float stage, and 13.5V storage. For an Epoch battery bank, confirm and enter the charging values for the exact battery model before commissioning.

Smart charger features

Wireless setup, wired integration, protection, and quiet fanless operation.

50A primary output Rapid shore-power charging for a substantial 12V house battery bank.
4A starter output Maintains a separate starter battery while the primary output charges the house bank.
Lithium charging mode Built-in 14.2V lithium absorption profile with no conventional float stage.
Fully programmable Customize voltage, current, operating mode, alarms, and relay behavior through supported interfaces.
Bluetooth Smart Use VictronConnect for setup, status, history, configuration, and firmware updates.
VE.Direct integration Connect to a compatible GX device, PC, or other supported interface.
Universal AC input Operates from 85–250VAC at 45–65Hz for North American and international shore power.
Adjustable AC input limit Set maximum AC input current from 3A to 10A for limited shore or generator sources.
Power-supply mode Provides a configurable fixed DC output for testing or compatible DC loads.
Automatic cable compensation Helps compensate for voltage drop across correctly sized DC cabling.
Natural convection cooling Fanless operation reduces noise and moving parts.
Built-in protections Includes reverse-polarity fuse protection, output short-circuit protection, and overtemperature protection.

Compatible applications

Marine, RV, leisure, off-grid, industrial, and battery-maintenance systems.

  • Marine shore-power charging for a 12V house bank plus a starter battery.
  • RV and camper shore-power charging with a separate chassis or starter battery.
  • Epoch 12V LiFePO4 battery banks configured to the battery’s published charge settings.
  • AGM, GEL, flooded lead-acid, and other compatible 12V battery systems.
  • Generator-powered charging where the AC input-current limit is configured to the available source.
  • GX-connected installations using VE.Direct and a compatible Cerbo GX or other GX device.
  • Fixed-output DC power-supply applications within the charger’s published ratings.
  • Redundant or synchronised charging with compatible Smart IP43 chargers and VE.Smart Networking.

Built for Global Shore Power

Universal 120/240V-class input for marinas, campgrounds, generators, and international installations.

The charger operates from 85–250VAC at 45–65Hz, reaches full rated output from 100VAC, and can start at approximately 90VAC. A configurable 3–10A AC input-current limit helps match charging demand to a smaller generator or limited shore-power circuit.

The charger uses an IEC C14 AC inlet with an included retainer clip. A country-specific AC mains cord is ordered separately.

Recommended accessories

Complete the charger installation with the correct AC cord, data cable, monitoring, and DC protection.

Victron ADA010100400 NEMA 5-15P mains cord for North American 120V outlets.
Victron VE.Direct cable in the appropriate length for a compatible GX device.
Victron Cerbo GX or Ekrano GX for system integration and VRM remote monitoring.
Victron Smart Battery Sense, SmartShunt, or BMV-712 Smart for optional VE.Smart voltage and temperature sensing.
Correctly sized DC cables, battery-side fuse, lugs, and strain relief for a 50A charging circuit.

Technical specifications

Exact electrical, charging, communication, environmental, and mechanical details.

Identification
Manufacturer Victron Energy
Product Phoenix / Smart IP43 Charger 12/50 (1+1) 120–240V
Part number PSC125051095
Product type Adaptive AC-to-DC battery charger and configurable DC power supply
Warranty 5-year standard Victron warranty, subject to Victron warranty terms
AC Input
AC input range 85–250VAC; full power from 100VAC; startup from approximately 90VAC
Frequency 45–65Hz
DC input range 90–375VDC
Maximum AC input-current setting 3–10A
Power factor 1
No-load consumption 1W
AC connection IEC C14 inlet with retainer clip; country-specific mains cord ordered separately
Charging Outputs
Primary / house-bank output 50A maximum
Low-current mode 25A
Secondary / starter-battery output 4A maximum; intended for starter-battery top-up
Battery connections Two: one main house-bank output plus one limited starter output
Maximum efficiency 94% for the 12/50 model
Back-current drain <1mA
Charge Profiles
Normal mode 14.4V absorption / 13.8V float / 13.2V storage
High mode 14.7V absorption / 13.8V float / 13.2V storage
Lithium mode 14.2V absorption / no conventional float / 13.5V storage
Lead-acid algorithm Adaptive 6-stage: bulk, absorption, recondition, float, storage, refresh
Lithium algorithm 3-stage
Custom programming Yes, through Bluetooth and/or VE.Direct
Power-supply mode Yes; output voltage configurable through Bluetooth and/or VE.Direct
Connectivity and Controls
Bluetooth Bluetooth Smart built in; VictronConnect compatible
VE.Direct Wired connection to compatible GX devices, PCs, and supported interfaces
Remote on/off Yes, two-pole terminal
Programmable relay SPDT; 5A up to 250VAC or 5A up to 28VDC
VE.Smart Networking Supports synchronised charging and compatible remote voltage/temperature sensing
Protection and Environment
Protection Battery reverse polarity via internal non-user-accessible fuse; output short circuit; overtemperature
Electronics ingress rating IP43
Connection-area ingress rating IP22
Operating temperature -20°C to 60°C / -4°F to 140°F
Output derating Full rated output to 40°C; linearly derated to 20% at 60°C
Humidity Maximum 95%, non-condensing
Cooling Natural convection; no cooling fan
Mechanical
Enclosure Aluminum, Victron blue RAL 5012
Battery connection 16mm² / AWG 6 screw terminals
Approximate dimensions 180 × 249 × 100mm / 7.1 × 9.8 × 3.9 in
Approximate weight 3.5kg / 7.7 lb
Mounting Vertical wall mounting in a dry, ventilated, protected location
Standards
Safety EN 60335-1 and EN 60335-2-29
Emission EN 55014-1, EN 61000-6-3, EN 61000-3-2
Immunity EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 61000-3-3
Vibration IEC 68-2-6: 10–150Hz / 1.0G

Installation and charging note

Use the correct mains cord, DC cabling, overcurrent protection, battery profile, and mounting location.

The country-specific AC cord is sold separately. Size the DC conductors and battery-side fuse for the 50A charging circuit, observe polarity, mount the charger vertically with adequate ventilation, and program the charging profile to the exact battery manufacturer’s specifications. Installation should be completed by a qualified person where marine, RV, or electrical codes require it.

Frequently asked questions

Victron Phoenix Smart IP43 12/50 (1+1) FAQs

Common questions about dual outputs, lithium settings, shore power, accessories, monitoring, and installation.

What does the “1+1” mean in the charger name?

The 1+1 designation means the charger has one primary 50A output for a 12V house battery bank plus one secondary starter-battery output rated at 4A maximum. The secondary output is intended to maintain or top up a starter battery; it is not a second independently controlled 50A charging channel.

Does the charger include an AC mains cord?

No. The charger uses an IEC C14 AC inlet with a retainer clip, and the country-specific mains cord is ordered separately. North American installations typically use Victron part ADA010100400, the 2-meter NEMA 5-15P mains cord, after confirming the outlet and installation requirements.

Can I use this charger with Epoch 12V LiFePO4 batteries?

Yes, provided the charger is configured to match the exact battery model. The built-in lithium mode uses 14.2V absorption, no conventional float stage, and 13.5V storage. VictronConnect and VE.Direct also allow a fully programmable profile, so use the charging values published for your specific Epoch battery.

Can I reduce the charging rate when using a small generator or limited shore-power outlet?

Yes. The charger supports a configurable maximum AC input-current setting from 3A to 10A, and the front-panel low-current mode limits the 12/50 model to 25A DC output. Configure the limit for the available AC source and verify that the generator or shore circuit can support the total connected load.

Can I plug it into both 120V and 230V shore power?

Yes. This 120/240V model operates from 85–250VAC at 45–65Hz, delivers full output from 100VAC, and can start from approximately 90VAC. Use the correct country-specific mains cord, branch-circuit protection, and shore-power connection for the installation.

Is the Phoenix Smart IP43 charger waterproof?

No. The electronics enclosure is rated IP43 and the connection area is IP22. Install the charger vertically in a dry, protected, well-ventilated location where the AC inlet, DC terminals, VE.Direct port, and controls are not exposed to direct spray, standing water, or condensation.

Can the secondary output charge a completely discharged starter battery?

The secondary output is limited to 4A maximum and is intended primarily for starter-battery maintenance and top-up charging. Recovery time for a deeply discharged starter battery can be long, and the battery must be compatible with the selected charging profile.

Can I monitor the charger remotely?

Bluetooth provides local monitoring and configuration through VictronConnect. For wider system integration, connect the VE.Direct port to a compatible GX device such as a Cerbo GX, then use the Victron Remote Management portal when the GX device has internet access.

Does this charger also function as an inverter?

No. It is an AC-to-DC battery charger and configurable DC power supply. It does not convert battery DC power back into 120V AC. A Victron MultiPlus or MultiPlus-II is the appropriate product category when both charging and inverter functionality are required.

Can it charge AGM, GEL, flooded lead-acid, and lithium batteries?

Yes. The charger provides selectable normal, high, and lithium modes and can be fully programmed through Bluetooth or VE.Direct. Lead-acid batteries use the adaptive six-stage algorithm, while the lithium profile uses a three-stage algorithm. Always select settings approved by the battery manufacturer.