Complete technical details for the Epoch 12V 460Ah MC - V2 Elite Series LiFePO4 Battery. Ratings at 25°C unless noted.
General
BrandEpoch Batteries
Model / SKUC12460C
Product nameEpoch 12V 460Ah MC - V2 Elite Series LiFePO4 Battery
SeriesV2 Elite Series
Battery typeBluetooth LiFePO4 deep-cycle battery with Victron communication
ChemistryLiFePO4 / Lithium iron phosphate
Cell configuration4S2P (230Ah cells)
BluetoothYes — Bluetooth 4.0 in the included State of Charge meter; Epoch Cloud app (iOS and Android)
Victron communicationsYes — CAN bus at 500 kbit/s; VICTRON and CAN RJ45 ports; DVCC via a compatible GX device
Internal heatingNo — charge only between 0°C and 55°C (32°F and 131°F)
Remote power switchIncluded — 16 mm illuminated push button on a 9.8 m (32.2 ft) cable
State of Charge meterIncluded, with Bluetooth and communication harness
Cycle life> 3,500 cycles to 70% capacity (25°C, 0.5C charge, 1C discharge, 70% DoD)
MaintenanceMaintenance-free
Voltage and capacity
Nominal voltage12.8V (3.2V per cell)
Nominal capacity460Ah (0.5C, 25°C)
Energy stored5,888Wh / 5.89kWh (0.5C, 25°C)
Operating voltage range10V – 14.6V
Maximum charge voltage14.6V (3.65V per cell)
Minimum voltage10V (2.5V per cell)
Self-discharge≤3% per month (100% SOC, 25°C)
Insulation resistance≥20 MΩ at 1,000V DC (25 ± 5°C, 50% RH)
Usable state of charge0–100%
State of charge at shipment30% ± 3%; charge fully before first use
Current ratings
Max continuous discharge230A (0.5C) at 25°C, 50% SOC — also the recommended discharge current
Peak discharge500A for up to 10 seconds (25°C, 50% SOC)
Max continuous charge current230A (0.5C) at 25°C, 50% SOC — also the recommended charge current
Peak charge400A for up to 5 seconds (25°C, 50% SOC)
Continuous power at 12.8VAbout 2,944W DC (before inverter losses)
Deep-cycle ratingNot cranking-rated; not for engine starting
Series and parallel configuration
Series connectionsUp to 4 batteries in series (51.2V nominal, 48V class)
Parallel connectionsUp to 16 batteries in parallel (7,360Ah; 94.2kWh)
Series-parallelNot supported
Bank communicationDaisy-chained CAN network (no branches or tees); one Master, all others Members, set by DIP switches
Matched batteriesUse only matched C12460C batteries of similar age, condition and firmware, at the same state of charge
Temperature
Charge temperature range0°C to 55°C / 32°F to 131°F
Discharge temperature range-20°C to 55°C / -4°F to 131°F
Short-term storage temperature-20°C to 45°C / -4°F to 113°F, up to 1 month
Recommended storage temperature0°C to 35°C / 32°F to 95°F, up to 1 year
Cooling methodPassive (natural convection)
Temperature protectionBMS shuts down outside the charge and discharge temperature ranges
Dimensions and weight
Overall length23.2 in / 589 mm (including mounting brackets)
Length without brackets21.5 in / 545.3 mm
Width7.5 in / 190 mm
Overall height15.2 in / 385 mm (including terminal covers)
Height without terminal covers13.6 in / 345 mm
Dimension tolerance± 2 mm length and height; ± 1.5 mm width
Weight105.8 ± 8.8 lb / 48 ± 4 kg
Mechanical
Enclosure protectionIP65 per IEC 60529: dust-tight and protected against water jets, with all covers and connectors installed. Not rated for immersion
Terminal typeCovered bolt terminals (hinged covers: positive orange, negative black)
Terminal torque12 N·m (8.85 lb·ft) maximum
MountingMounting brackets at both ends (included); install upright
Communication portsVICTRON and CAN (RJ45) on the terminal panel
External switch4-pin circular EXTERNAL SWITCH connector
Recommended charging settings
Charge profileLiFePO4, CC/CV; program every charge source, including Victron equipment, to these settings
Recommended charge current230A (0.5C) per battery
Bulk / absorption voltage14.2V
Absorption time15 minutes per battery in the bank
Charge termination (CC/CV)Current ≤ 0.02C (9.2A)
Float voltage13.5V
EqualizationDisabled
Temperature compensationDisabled (0 mV/°C)
Never exceed14.6V (3.65V per cell)
Alternator chargingDC-to-DC charger programmed for LiFePO4 highly recommended
Victron setupTurn DVCC on and set the controlling BMS and the battery monitor to Epoch on a compatible GX device
BMS protection
Over-voltageMaximum voltage 14.6V (3.65V per cell)
Under-voltageAlarm, then shutdown; minimum voltage 10V (2.5V per cell)
Over-currentShutdown above the current ratings (500A for 10 s discharge; 400A for 5 s charge)
Over-temperatureShutdown outside the temperature ranges (charge 0°C to 55°C; discharge -20°C to 55°C)
Short circuitShutdown on an external short circuit
Compliance and warranty
Cell-level certificationGB/T certificate
EnclosureIP65 per IEC 60529
Pack-level certificatesContact Epoch Batteries for current pack-level certificates and listings
Warranty11-year limited manufacturer warranty. Register within 90 days of purchase for full coverage.